siemens dk_standard_ethernet_controller_evaluation_kit_firmware 不加限制或调节的资源分配

CVE编号

CVE-2020-28400

利用情况

暂无

补丁情况

N/A

披露时间

2021-07-13
漏洞描述
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 (All versions), Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P (All versions), RUGGEDCOM RM1224 (All Versions < 6.4), SCALANCE M-800 (All Versions < 6.4), SCALANCE S615 (All Versions < 6.4), SCALANCE W1700 IEEE 802.11ac (All versions), SCALANCE W700 IEEE 802.11n (All versions), SCALANCE X200-4 P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT (All Versions < V5.5.0), SCALANCE X201-3P IRT PRO (All Versions < V5.5.0), SCALANCE X202-2 IRT (All Versions < V5.5.0), SCALANCE X202-2P IRT (incl. SIPLUS NET variant) (All Versions < V5.5.0), SCALANCE X202-2P IRT PRO (All Versions < V5.5.0), SCALANCE X204 IRT (All Versions < V5.5.0), SCALANCE X204 IRT PRO (All Versions < V5.5.0), SCALANCE X204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2FM (All versions), SCALANCE X204-2LD (incl. SIPLUS NET variant) (All versions), SCALANCE X204-2LD TS (All versions), SCALANCE X204-2TS (All versions), SCALANCE X206-1 (All versions), SCALANCE X206-1LD (incl. SIPLUS NET variant) (All versions), SCALANCE X208 (incl. SIPLUS NET variant) (All versions), SCALANCE X208PRO (All versions), SCALANCE X212-2 (All versions), SCALANCE X212-2LD (All versions), SCALANCE X216 (All versions), SCALANCE X224 (All versions), SCALANCE X302-7EEC (All versions), SCALANCE X304-2FE (All versions), SCALANCE X306-1LDFE (All versions), SCALANCE X307-2EEC (All versions), SCALANCE X307-3 (All versions), SCALANCE X307-3LD (All versions), SCALANCE X308-2 (incl. SIPLUS NET variant) (All versions), SCALANCE X308-2LD (All versions), SCALANCE X308-2LH (All versions), SCALANCE X308-2LH+ (All versions), SCALANCE X308-2M (All versions), SCALANCE X308-2M POE (All versions), SCALANCE X308-2M TS (All versions), SCALANCE X310 (All versions), SCALANCE X310FE (All versions), SCALANCE X320-1FE (All versions), SCALANCE X320-3LDFE (All versions), SCALANCE XB-200 (All versions), SCALANCE XC-200 (All versions), SCALANCE XF-200BA (All versions), SCALANCE XF201-3P IRT (All Versions < V5.5.0), SCALANCE XF202-2P IRT (All Versions < V5.5.0), SCALANCE XF204 (All versions), SCALANCE XF204 IRT (All Versions < V5.5.0), SCALANCE XF204-2 (incl. SIPLUS NET variant) (All versions), SCALANCE XF204-2BA IRT (All Versions < V5.5.0), SCALANCE XF206-1 (All versions), SCALANCE XF208 (All versions), SCALANCE XM400 (All versions < V6.3.1), SCALANCE XP-200 (All versions), SCALANCE XR-300WG (All versions), SCALANCE XR324-12M (All versions), SCALANCE XR324-12M TS (All versions), SCALANCE XR324-4M EEC (All versions), SCALANCE XR324-4M POE (All versions), SCALANCE XR324-4M POE TS (All versions), SCALANCE XR500 (All versions < V6.3.1), SIMATIC CFU PA (All versions), SIMATIC IE/PB-LINK V3 (All versions), SIMATIC MV500 family (All versions < V3.0), SIMATIC NET CM 1542-1 (All versions), SIMATIC NET CP1616/CP1604 (All Versions >= V2.7), SIMATIC NET CP1626 (All versions), SIMATIC NET DK-16xx PN IO (All Versions >= V2.7), SIMATIC PROFINET Driver (All versions), SIMATIC Power Line Booster PLB, Base Module (MLFB: 6ES7972-5AA10-0AB0) (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All Versions < V4.5), SIMOCODE proV Ethernet/IP (All versions < V1.1.3), SIMOCODE proV PROFINET (All versions < V2.1.3), SOFTNET-IE PNIO (All versions). Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
解决建议
建议您更新当前系统或软件至最新版,完成漏洞的修复。
受影响软件情况
# 类型 厂商 产品 版本 影响面
1
运行在以下环境
系统 siemens dk_standard_ethernet_controller_evaluation_kit_firmware * -
运行在以下环境
系统 siemens ek-ertec_200p_evaluation_kit_firmware * -
运行在以下环境
系统 siemens ek-ertec_200_evaulation_kit_firmware * -
运行在以下环境
系统 siemens ruggedcom_rm1224_firmware * Up to
(excluding)
6.4
运行在以下环境
系统 siemens scalance_m-800_firmware * Up to
(excluding)
6.4
运行在以下环境
系统 siemens scalance_s615_firmware * Up to
(excluding)
6.4
运行在以下环境
系统 siemens scalance_w1700_firmware * -
运行在以下环境
系统 siemens scalance_w700_firmware * -
运行在以下环境
系统 siemens scalance_x200-4_p_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x201-3p_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x201-3p_irt_pro_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x202-2p_irt_pro_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x202-2_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x204-2fm_firmware * -
运行在以下环境
系统 siemens scalance_x204-2ld_firmware * -
运行在以下环境
系统 siemens scalance_x204-2ld_ts_firmware * -
运行在以下环境
系统 siemens scalance_x204-2ts_firmware * -
运行在以下环境
系统 siemens scalance_x204-2_firmware * -
运行在以下环境
系统 siemens scalance_x204_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x204_irt_pro_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_x206-1ld_firmware * -
运行在以下环境
系统 siemens scalance_x206-1_firmware * -
运行在以下环境
系统 siemens scalance_x208pro_firmware * -
运行在以下环境
系统 siemens scalance_x208_firmware * -
运行在以下环境
系统 siemens scalance_x212-2ld_firmware * -
运行在以下环境
系统 siemens scalance_x212-2_firmware * -
运行在以下环境
系统 siemens scalance_x216_firmware * -
运行在以下环境
系统 siemens scalance_x224_firmware * -
运行在以下环境
系统 siemens scalance_x302-7eec_firmware * -
运行在以下环境
系统 siemens scalance_x304-2fe_firmware * -
运行在以下环境
系统 siemens scalance_x306-1ldfe_firmware * -
运行在以下环境
系统 siemens scalance_x307-2eec_firmware * -
运行在以下环境
系统 siemens scalance_x307-3ld_firmware * -
运行在以下环境
系统 siemens scalance_x307-3_firmware * -
运行在以下环境
系统 siemens scalance_x308-2ld_firmware * -
运行在以下环境
系统 siemens scalance_x308-2lh+_firmware * -
运行在以下环境
系统 siemens scalance_x308-2lh_firmware * -
运行在以下环境
系统 siemens scalance_x308-2m_firmware * -
运行在以下环境
系统 siemens scalance_x308-2m_poe_firmware * -
运行在以下环境
系统 siemens scalance_x308-2m_ts_firmware * -
运行在以下环境
系统 siemens scalance_x308-2_firmware * -
运行在以下环境
系统 siemens scalance_x310fe_firmware * -
运行在以下环境
系统 siemens scalance_x310_firmware * -
运行在以下环境
系统 siemens scalance_x320-1fe_firmware * -
运行在以下环境
系统 siemens scalance_x320-3ldfe_firmware * -
运行在以下环境
系统 siemens scalance_xb-200_firmware * -
运行在以下环境
系统 siemens scalance_xc-200_firmware * -
运行在以下环境
系统 siemens scalance_xf-200ba_firmware * -
运行在以下环境
系统 siemens scalance_xf201-3p_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_xf202-2p_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_xf204-2ba_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_xf204-2_firmware * -
运行在以下环境
系统 siemens scalance_xf204_firmware * -
运行在以下环境
系统 siemens scalance_xf204_irt_firmware * Up to
(excluding)
5.5.0
运行在以下环境
系统 siemens scalance_xf206-1_firmware * -
运行在以下环境
系统 siemens scalance_xf208_firmware * -
运行在以下环境
系统 siemens scalance_xm400_firmware * Up to
(excluding)
6.3.1
运行在以下环境
系统 siemens scalance_xp-200_firmware * -
运行在以下环境
系统 siemens scalance_xr-300wg_firmware * -
运行在以下环境
系统 siemens scalance_xr324-12m_firmware * -
运行在以下环境
系统 siemens scalance_xr324-12m_ts_firmware * -
运行在以下环境
系统 siemens scalance_xr324-4m_eec_firmware * -
运行在以下环境
系统 siemens scalance_xr324-4m_poe_firmware * -
运行在以下环境
系统 siemens scalance_xr324-4m_poe_ts_firmware * -
运行在以下环境
系统 siemens scalance_xr500_firmware * Up to
(excluding)
6.3.1
运行在以下环境
系统 siemens simatic_cfu_pa_firmware * -
运行在以下环境
系统 siemens simatic_ie/pb-link_v3_firmware * -
运行在以下环境
系统 siemens simatic_mv500_firmware * Up to
(excluding)
3.0
运行在以下环境
系统 siemens simatic_net_cm_1542-1_firmware * -
运行在以下环境
系统 siemens simatic_net_cp1604_firmware * Up to
(including)
2.7
运行在以下环境
系统 siemens simatic_net_cp1616_firmware * Up to
(including)
2.7
运行在以下环境
系统 siemens simatic_net_cp1626_firmware * -
运行在以下环境
系统 siemens simatic_power_line_booster_plb_firmware * -
运行在以下环境
系统 siemens simatic_profinet_driver_firmware * -
运行在以下环境
系统 siemens simatic_s7-1200_firmware * -
运行在以下环境
系统 siemens simocode_prov_ethernet/ip_firmware * -
运行在以下环境
系统 siemens simocode_prov_profinet_firmware * -
运行在以下环境
系统 siemens softnet-ie_pnio_firmware * -
运行在以下环境
硬件 siemens dk_standard_ethernet_controller_evaluation_kit - -
运行在以下环境
硬件 siemens ek-ertec_200p_evaluation_kit - -
运行在以下环境
硬件 siemens ek-ertec_200_evaulation_kit - -
运行在以下环境
硬件 siemens ruggedcom_rm1224 - -
运行在以下环境
硬件 siemens scalance_m-800 - -
运行在以下环境
硬件 siemens scalance_s615 - -
运行在以下环境
硬件 siemens scalance_w1700 - -
运行在以下环境
硬件 siemens scalance_w700 - -
运行在以下环境
硬件 siemens scalance_x200-4_p_irt - -
运行在以下环境
硬件 siemens scalance_x201-3p_irt - -
运行在以下环境
硬件 siemens scalance_x201-3p_irt_pro - -
运行在以下环境
硬件 siemens scalance_x202-2p_irt_pro - -
运行在以下环境
硬件 siemens scalance_x202-2_irt - -
运行在以下环境
硬件 siemens scalance_x204-2fm - -
运行在以下环境
硬件 siemens scalance_x204-2ld - -
运行在以下环境
硬件 siemens scalance_x204-2ld_ts - -
运行在以下环境
硬件 siemens scalance_x204-2ts - -
运行在以下环境
硬件 siemens scalance_x204-2_ - -
运行在以下环境
硬件 siemens scalance_x204_irt - -
运行在以下环境
硬件 siemens scalance_x204_irt_pro - -
运行在以下环境
硬件 siemens scalance_x206-1 - -
运行在以下环境
硬件 siemens scalance_x206-1ld - -
运行在以下环境
硬件 siemens scalance_x208 - -
运行在以下环境
硬件 siemens scalance_x208pro - -
运行在以下环境
硬件 siemens scalance_x212-2 - -
运行在以下环境
硬件 siemens scalance_x212-2ld - -
运行在以下环境
硬件 siemens scalance_x216 - -
运行在以下环境
硬件 siemens scalance_x224 - -
运行在以下环境
硬件 siemens scalance_x302-7eec - -
运行在以下环境
硬件 siemens scalance_x304-2fe - -
运行在以下环境
硬件 siemens scalance_x306-1ldfe - -
运行在以下环境
硬件 siemens scalance_x307-2eec - -
运行在以下环境
硬件 siemens scalance_x307-3 - -
运行在以下环境
硬件 siemens scalance_x307-3ld - -
运行在以下环境
硬件 siemens scalance_x308-2 - -
运行在以下环境
硬件 siemens scalance_x308-2ld - -
运行在以下环境
硬件 siemens scalance_x308-2lh - -
运行在以下环境
硬件 siemens scalance_x308-2lh+ - -
运行在以下环境
硬件 siemens scalance_x308-2m - -
运行在以下环境
硬件 siemens scalance_x308-2m_poe - -
运行在以下环境
硬件 siemens scalance_x308-2m_ts - -
运行在以下环境
硬件 siemens scalance_x310 - -
运行在以下环境
硬件 siemens scalance_x310fe - -
运行在以下环境
硬件 siemens scalance_x320-1fe - -
运行在以下环境
硬件 siemens scalance_x320-3ldfe - -
运行在以下环境
硬件 siemens scalance_xb-200 - -
运行在以下环境
硬件 siemens scalance_xc-200 - -
运行在以下环境
硬件 siemens scalance_xf-200ba - -
运行在以下环境
硬件 siemens scalance_xf201-3p_irt - -
运行在以下环境
硬件 siemens scalance_xf202-2p_irt - -
运行在以下环境
硬件 siemens scalance_xf204 - -
运行在以下环境
硬件 siemens scalance_xf204-2ba_irt - -
运行在以下环境
硬件 siemens scalance_xf204-2_ - -
运行在以下环境
硬件 siemens scalance_xf204_irt - -
运行在以下环境
硬件 siemens scalance_xf206-1 - -
运行在以下环境
硬件 siemens scalance_xf208 - -
运行在以下环境
硬件 siemens scalance_xm400 - -
运行在以下环境
硬件 siemens scalance_xp-200 - -
运行在以下环境
硬件 siemens scalance_xr-300wg - -
运行在以下环境
硬件 siemens scalance_xr324-12m - -
运行在以下环境
硬件 siemens scalance_xr324-12m_ts - -
运行在以下环境
硬件 siemens scalance_xr324-4m_eec - -
运行在以下环境
硬件 siemens scalance_xr324-4m_poe - -
运行在以下环境
硬件 siemens scalance_xr324-4m_poe_ts - -
运行在以下环境
硬件 siemens scalance_xr500 - -
运行在以下环境
硬件 siemens simatic_cfu_pa - -
运行在以下环境
硬件 siemens simatic_ie/pb-link_v3 - -
运行在以下环境
硬件 siemens simatic_mv500 - -
运行在以下环境
硬件 siemens simatic_net_cm_1542-1 - -
运行在以下环境
硬件 siemens simatic_net_cp1604 - -
运行在以下环境
硬件 siemens simatic_net_cp1616 - -
运行在以下环境
硬件 siemens simatic_net_cp1626 - -
运行在以下环境
硬件 siemens simatic_power_line_booster_plb - -
运行在以下环境
硬件 siemens simatic_profinet_driver - -
运行在以下环境
硬件 siemens simatic_s7-1200 - -
运行在以下环境
硬件 siemens simocode_prov_ethernet/ip - -
运行在以下环境
硬件 siemens simocode_prov_profinet - -
运行在以下环境
硬件 siemens softnet-ie_pnio - -
CVSS3评分
7.5
  • 攻击路径
    网络
  • 攻击复杂度
  • 权限要求
  • 影响范围
    未更改
  • 用户交互
  • 可用性
  • 保密性
  • 完整性
CWE-ID 漏洞类型
CWE-770 不加限制或调节的资源分配
阿里云安全产品覆盖情况